05/07/2021 | FRAMING | | CANCELLED | Cancelled by IVR at 05/06/2021 13:26 | |
|
05/11/2021 | PLUMBING ROUGH | JEFF CHUBY | APPROVED | eTRAKiT Inspection Request | 5/10/2021 4:01:26 PM
5/10/2021 4:01 PM ULTIMATE PLUMBING & REPAIR INC
Contact Name: ULTIMATE PLUMBING & REPAIR INC
Site Address: 128 WILD HARBOR RD
Phone: 7048925843
e-Mail: ultimateplumbinginc@gmail.com
|
|
05/11/2021 | GAS PIPING ROUGH | JEFF CHUBY | APPROVED | eTRAKiT Inspection Request | 5/10/2021 4:01:48 PM
5/10/2021 4:01 PM ULTIMATE PLUMBING & REPAIR INC
Contact Name: ULTIMATE PLUMBING & REPAIR INC
Site Address: 128 WILD HARBOR RD
Phone: 7048925843
e-Mail: ultimateplumbinginc@gmail.com
|
|
05/12/2021 | SHEATHING AND FLASHING | JEFF CHUBY | APPROVED | | |
|
05/12/2021 | FRAMING | JEFF CHUBY | REJECTED | | 5/12/2021 1:42:37 PM
Firestop at finished ceiling heights and around tub drains; need Electrical permit and inspection (open junction boxes between floors, etc.)
|
|
| ELEC UNDERGROUND | | | | |
|
| ELECTRICAL SLAB | | | | |
|
05/14/2021 | ELECTRICAL ROUGH | STEPHEN SANDERS | APPROVED | eTRAKiT Inspection Request | 5/13/2021 12:58:20 PM
5/13/2021 12:58 PM TRITON ELECTRIC COMPANY
Contact Name: TRITON ELECTRIC COMPANY
Site Address: 128 WILD HARBOR RD
Phone: 7048219953
e-Mail: TRITONELECTRICCO@AOL.COM
|
|
05/14/2021 | FRAMING | STEPHEN SANDERS | APPROVED | | |
|
| FRAMING | STEPHEN SANDERS | | | |
|
05/18/2021 | INSULATION | JEFF CHUBY | REJECTED | | 5/18/2021 1:20:51 PM
Insulate under floor of garage area framing; energy zone 4 requires R-15 in walls, R-19 in floors and R-38 in ceilings; remove paper from insulation in exposed areas and install proper air-barrier (paper states "THIS FACING WILL BRN, DO NOT LEAVE EXPOSED", paper shall be installed to the warm air side (towards conditioned space).
|
|
| INSULATION | | | | |
|
05/24/2021 | INSULATION | JEFF CHUBY | APPROVED | | |
|
06/03/2021 | SHOWER PAN | JEFF CHUBY | APPROVED | | 6/3/2021 12:01:31 PM
Schleuter system pan
|
|
08/25/2021 | GAS PIPING FINAL | JEFF CHUBY | APPROVED | eTRAKiT Inspection Request | 8/23/2021 12:14:46 PM
8/23/2021 12:14 PM ULTIMATE PLUMBING
Gas cook top connection
Contact Name: ULTIMATE PLUMBING
Site Address: 128 WILD HARBOR RD
Phone: 7048925843
e-Mail: ultimateplumbinginc@gmail.com
|
|
08/25/2021 | PLUMBING FINAL CERT OF COMP | JEFF CHUBY | APPROVED | eTRAKiT Inspection Request | 8/20/2021 3:40:55 PM
8/20/2021 3:40 PM ULTIMATE PLUMBING
final inspection. kitchen trim, mb trim, j&j bath trim, bar sink trim
Contact Name: ULTIMATE PLUMBING
Site Address: 128 WILD HARBOR RD
Phone: 7048925843
e-Mail: ultimateplumbinginc@gmail.com
8/23/2021 12:22:21 PM
8/23/2021 12:22 PM ULTIMATE PLUMBING
2-- bathrooms upstairs trim, island sink trim
Contact Name: ULTIMATE PLUMBING
Site Address: 128 WILD HARBOR RD
Phone: 7048925843
e-Mail: ultimateplumbinginc@gmail.com
|
|
04/14/2022 | BLDG FINAL CERT OF COMP | DANA LAPISH | APPROVED | | |
|
04/14/2022 | COMPLETE PERMIT** | DANA LAPISH | APPROVED | | |
|
04/14/2022 | ELECTRICAL FINAL CERT OF COMP | DANA LAPISH | APPROVED | | |
|