05/05/2024
10:56 AM

Iredell County Inspections Department

 
Permit No. AP-317010 Permit Type   BUILDING RESIDENTIAL Site Address   1109 YOUNG ST
MOORESVILLE, NC 28115
Applied   04/21/2021 Applicant  
Approved   04/21/2021 Owner   J2 LAND INVESTMENTS LLC
Issued   04/28/2021 Contractor   PRESPRO LLC
Parent Permit No.   Description   SINGLE FAMILY
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

GARAGE PORCH SLAB

SHOWER PAN

 05/18/2021FOOTINGJIMMY MEADOWSAPPROVED

 05/18/2021LOCATION SETBACKSJIMMY MEADOWSINCOMPLETE5/18/2021 12:59:16 PM need survey

 05/18/2021GRADING RESJIMMY MEADOWSREJECTED

 05/24/2021GRADING RESGARY WRIGHTAPPROVED

 05/24/2021LOCATION SETBACKSGARY WRIGHTAPPROVED5/18/2021 12:59:33 PM need survey

 05/24/2021FOUNDATIONGARY WRIGHTPARTIAL5/24/2021 11:50:33 AM foundation only

 05/25/2021FOUNDATIONGARY WRIGHTAPPROVED

 06/03/2021PLUMBING SLABGARY WRIGHTPARTIALeTRAKiT Inspection Request6/2/2021 11:38:16 AM 6/2/2021 11:38 AM RS LITTON PLUMBING LLC Contact Name: RS LITTON PLUMBING LLC Site Address: 1109 YOUNG ST Phone: 7045009034 e-Mail: rstaude@rslittonplumbing.com 6/3/2021 1:23:44 PM BWV installed , need certificate

PLUMBING SLABeTRAKiT Inspection Request

 06/14/2021SLABGARY WRIGHTAPPROVED

 06/21/2021SHEATHING AND FLASHINGGARY WRIGHTINCOMPLETE6/21/2021 12:31:19 PM not ready

 06/28/2021PLUMBING ROUGHGARY WRIGHTAPPROVEDeTRAKiT Inspection Request6/25/2021 7:47:33 AM 6/25/2021 7:47 AM RS LITTON PLUMBING LLC Contact Name: RS LITTON PLUMBING LLC Site Address: 1109 YOUNG ST Phone: 7045009034 e-Mail: rstaude@rslittonplumbing.com

 07/02/2021SAW SERVICEROB MOOSEAPPROVEDeTRAKiT Inspection Request7/1/2021 12:15:21 PM 7/1/2021 12:15 PM Estep Electrical Solutions Inc Contact Name: Estep Electrical Solutions Inc Site Address: 1109 YOUNG ST Phone: 9805211412 e-Mail: john@estepelectricalsolutions.com

 07/13/2021ELECTRICAL ROUGHGARY WRIGHTAPPROVEDlockbox 85907/12/2021 4:39:03 PM 7/12/2021 4:39 PM Estep Electrical Solutions Inc LOCKBOX 8590 Contact Name: Estep Electrical Solutions Inc Site Address: 1109 YOUNG ST Phone: 9805211412 e-Mail: john@estepelectricalsolutions.com

 07/15/2021SHEATHING AND FLASHINGGARY WRIGHTAPPROVED

 07/15/2021MECHANICAL ROUGHGARY WRIGHTAPPROVEDeTRAKiT Inspection Request7/14/2021 4:29:07 PM 7/14/2021 4:29 PM SUMMIT AIR & ELECTRIC LLC Contact Name: SUMMIT AIR & ELECTRIC LLC Site Address: 1109 YOUNG ST Phone: 7045970940 e-Mail: office@summitairandelectric.com

 07/15/2021FRAMINGGARY WRIGHTAPPROVED

 07/19/2021INSULATIONROB MOOSEREJECTED7/19/2021 12:57:50 PM plumbing vent boots were not installed and rain is splashing up on the insulation in back left of dwelling // also under the tubs were never sealed off to prevent moisture from entering the enclosed area

 07/22/2021INSULATIONROB MOOSEAPPROVED7/19/2021 12:57:55 PM plumbing vent boots were not installed and rain is splashing up on the insulation in back left of dwelling // also under the tubs were never sealed off to prevent moisture from entering the enclosed area

 08/23/2021SEWERROB MOOSEAPPROVEDeTRAKiT Inspection Request8/21/2021 7:10:22 AM 8/21/2021 7:10 AM RS LITTON PLUMBING LLC Contact Name: RS LITTON PLUMBING LLC Site Address: 1109 YOUNG ST Phone: 7045009034 e-Mail: rstaude@rslittonplumbing.com 8/23/2021 11:46:29 AM bwv installed 4ft from house, next to porch

 08/23/2021WATER SUPPLYROB MOOSEAPPROVEDeTRAKiT Inspection Request8/21/2021 7:10:40 AM 8/21/2021 7:10 AM RS LITTON PLUMBING LLC Contact Name: RS LITTON PLUMBING LLC Site Address: 1109 YOUNG ST Phone: 7045009034 e-Mail: rstaude@rslittonplumbing.com

 08/26/2021BLDG FINAL CERT OF COMPGARY WRIGHTREJECTEDeTRAKiT Inspection Request8/25/2021 12:01:27 PM 8/25/2021 12:01 PM RS LITTON PLUMBING LLC Door Code: 8590 Contact Name: RS LITTON PLUMBING LLC Site Address: 1109 YOUNG ST Phone: 7045009034 e-Mail: rstaude@rslittonplumbing.com 8/26/2021 1:30:39 PM need all trade finals passed, need energy envelope, need utility and zoning. backflow

 09/01/2021TEMPORARY POWERGARY WRIGHTAPPROVEDeTRAKiT Inspection Request8/31/2021 4:35:38 PM 8/31/2021 4:35 PM Estep Electrical Solutions Inc lockbox 8590 Contact Name: Estep Electrical Solutions Inc Site Address: 1109 YOUNG ST Phone: 9805211412 e-Mail: john@estepelectricalsolutions.com

 09/08/2021PLUMBING FINAL CERT OF COMPGARY WRIGHTAPPROVEDeTRAKiT Inspection Request9/7/2021 8:29:48 AM 9/7/2021 8:29 AM RS LITTON PLUMBING LLC Door Code: 8590 Contact Name: RS LITTON PLUMBING LLC Site Address: 1109 YOUNG ST Phone: 7045009034 e-Mail: rstaude@rslittonplumbing.com

 09/08/2021MECHANICAL FINAL CERT OF COMPGARY WRIGHTAPPROVEDeTRAKiT Inspection Request9/7/2021 1:07:41 PM 9/7/2021 1:07 PM SUMMIT AIR & ELECTRIC LLC LOCK BOX 8590 Contact Name: SUMMIT AIR & ELECTRIC LLC Site Address: 1109 YOUNG ST Phone: 7045970940 e-Mail: office@summitairandelectric.com

 09/09/2021ELECTRICAL FINAL CERT OF COMPROB MOOSEAPPROVED9/7/2021 10:30:03 AM 9/7/2021 10:30 AM Estep Electrical Solutions Inc Contact Name: Estep Electrical Solutions Inc Site Address: 1109 YOUNG ST Phone: 9805211412 e-Mail: john@estepelectricalsolutions.com 9/8/2021 12:48:39 PM no power to outlets

ELECTRICAL FINAL CERT OF COMP

 09/22/2021BLDG FINAL CERT OF COMPGARY WRIGHTREJECTEDeTRAKiT Inspection Request9/22/2021 12:13:10 PM need utility and zoning. backflow

 09/24/2021UTILITY FINALGary L HarkeyAPPROVED

 09/24/2021ZONING FINALFrederick L CarterAPPROVED

 09/09/2021ENERGY ENVELOPEGARY WRIGHTAPPROVED

 09/28/2021BLDG FINAL CERT OF COMPGARY WRIGHTREJECTEDeTRAKiT Inspection Request9/28/2021 1:09:29 PM need backflow approval

BACKFLOWMARY A BOLIEKAPPROVED

 09/29/2021BLDG FINAL CERT OF COMPGARY WRIGHTAPPROVEDeTRAKiT Inspection Request

 09/29/2021CERT OF OCCUPANCYGARY WRIGHTAPPROVED

 09/29/2021COMPLETE PERMIT**GARY WRIGHTAPPROVED