05/04/2024
9:04 PM

Iredell County Inspections Department

 
Permit No. AP-301476 Permit Type   APPLICATION Site Address   240 MADELIA PL
MOORESVILLE, NC 28115
Applied   10/03/2019 Applicant   SHEA CUSTOM LLC
Approved   Owner   BOWSER MATTHEW P+JENNIFER M
Issued   10/17/2019 Contractor   SHEA CUSTOM LLC
Parent Permit No.   Description   SINGLE FAMILY HOME
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ELEC UNDERGROUND

ELECTRICAL SLAB

 11/05/2019FOOTINGRANDY TRIVETTEPARTIAL11/5/2019 2:20:17 PM partial-ok pending soil report

 11/27/2019FOUNDATIONRANDY TRIVETTEPARTIAL11/27/2019 12:14:24 PM BLOCK OK ,,NEED SLAB INSULATION ON INSIDE OF FOUNDATION WALL,,WILL CHECK AT SLAB

 12/04/2019PLUMBING SLABRANDY TRIVETTEAPPROVED

 12/04/2019SEWERRANDY TRIVETTEREJECTED12/4/2019 2:14:26 PM not ready

 12/04/2019WATER SUPPLYRANDY TRIVETTEREJECTED12/4/2019 2:14:30 PM not ready

 12/06/2019SEWERRANDY TRIVETTEAPPROVED12/4/2019 2:14:30 PM not ready

 12/06/2019WATER SUPPLYRANDY TRIVETTEAPPROVED12/4/2019 2:14:34 PM not ready

 12/06/2019FOUNDATIONRANDY TRIVETTEAPPROVED11/27/2019 12:14:28 PM BLOCK OK ,,NEED SLAB INSULATION ON INSIDE OF FOUNDATION WALL,,WILL CHECK AT SLAB

 12/06/2019SLABRANDY TRIVETTEAPPROVED

 12/20/2019SAW SERVICERANDY TRIVETTEAPPROVED

 12/20/2019SAW SERVICERANDY TRIVETTEAPPROVED

COMPLETE PERMIT**

 01/21/2020SHEATHING AND FLASHINGRANDY TRIVETTEAPPROVED

 01/28/2020SAW SERVICERANDY TRIVETTEAPPROVED

 01/28/2020PLUMBING ROUGHRANDY TRIVETTEAPPROVEDeTRAKiT Inspection Request1/27/2020 11:51:52 AM 1/27/2020 11:51 AM PRICE BROTHERS, INC Contact Name: PRICE BROTHERS, INC Site Address: 240 MADELIA PL Phone: 7045886110 e-Mail: PBIPURCHASING@PRICEBROTHERSINC.COM

 01/31/2020LOW VOLTAGE ROUGHRANDY TRIVETTEAPPROVED1/30/2020 10:13:03 AM 1/30/2020 10:13 AM CPI SECURITY SYSTEMS INC Contact Name: CPI SECURITY SYSTEMS INC Site Address: 240 MADELIA PL Phone: 7049456133 e-Mail: newconstruction@cpisecurity.com

 02/04/2020GAS PIPING ROUGHGARY WRIGHTAPPROVED

 02/04/2020MECHANICAL ROUGHGARY WRIGHTAPPROVED

 02/07/2020ELECTRICAL ROUGHGARY WRIGHTAPPROVED

 02/13/2020FRAMINGMARK POPEREJECTED2/13/2020 4:28:25 PM * missing nuts,washers & anchor bolts @ various places * concealed flange hanger @ cantilevered LVL in garage install incorrectly (needs to be inverted per plan) * confirm that truss hangers on 10-C trusses(bonus rm) are correct * missing simpson hold down brackets per plan * seal holes/gaps @ PL pipes @ sole plate( various places) * tighten crack/gap @ 2 ply girder truss @ upstairs front gable wall *

 02/19/2020FIREPLACE ROUGHMARK POPEAPPROVED

 02/19/2020FRAMINGMARK POPEPARTIAL2/19/2020 2:33:04 PM * need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE *

 02/21/2020FRAMINGRANDY TRIVETTEAPPROVED2/13/2020 4:28:58 PM * missing nuts,washers & anchor bolts @ various places * concealed flange hanger @ cantilevered LVL in garage install incorrectly (needs to be inverted per plan) * confirm that truss hangers on 10-C trusses(bonus rm) are correct * missing simpson hold down brackets per plan * seal holes/gaps @ PL pipes @ sole plate( various places) * tighten crack/gap @ 2 ply girder truss @ upstairs front gable wall * 2/19/2020 2:33:08 PM * need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE * 2/21/2020 1:25:50 PM engineer letter in file on leaving hanger on lvl in garage right side up

 02/21/2020FRAMINGRANDY TRIVETTEAPPROVED2/21/2020 2:44:50 PM eng letter in file for inverted hanger

 02/26/2020INSULATIONRANDY TRIVETTEAPPROVED

INSULATIONRANDY TRIVETTE

 03/17/2020SHOWER PANRANDY TRIVETTEAPPROVEDeTRAKiT Inspection Request3/16/2020 10:12:19 AM 3/16/2020 10:12 AM PRICE BROTHERS, INC Contact Name: PRICE BROTHERS, INC Site Address: 240 MADELIA PL Phone: 7045886110 e-Mail: dray@PRICEBROTHERSINC.COM

 04/06/2020GAS PIPING FINALRANDY TRIVETTEAPPROVED

 04/07/2020MECHANICAL FINAL CERT OF COMPRANDY TRIVETTEAPPROVED

 04/09/2020LOW VOLTAGE FINALRONNIE BROOMEAPPROVED4/8/2020 1:59:46 PM 4/8/2020 1:59 PM CPI SECURITY SYSTEMS INC Contact Name: CPI SECURITY SYSTEMS INC Site Address: 240 MADELIA PL Phone: 7049456133 e-Mail: newconstruction@cpisecurity.com

 04/14/2020ELECTRICAL FINAL CERT OF COMPRANDY TRIVETTEREJECTED4/14/2020 2:51:31 PM need ground rods,,coach light on garage,,25amp max breaker on #1 A/C

 04/14/2020PLUMBING FINAL CERT OF COMPRANDY TRIVETTEAPPROVEDeTRAKiT Inspection Request4/13/2020 3:56:22 PM 4/13/2020 3:56 PM PRICE BROTHERS, INC Contact Name: PRICE BROTHERS, INC Site Address: 240 MADELIA PL Phone: 7045886110 e-Mail: pbipurchasing@PRICEBROTHERSINC.COM

 04/16/2020ELECTRICAL FINAL CERT OF COMPRANDY TRIVETTEREJECTED4/14/2020 2:51:36 PM need ground rods,,coach light on garage,,25amp max breaker on #1 A/C 4/16/2020 11:50:26 AM need IBT on grounding electrode per 250.94

 04/20/2020ELECTRICAL FINAL CERT OF COMPRANDY TRIVETTEAPPROVED4/16/2020 11:50:33 AM need ground rods,,coach light on garage,,25amp max breaker on #1 A/C 4/16/2020 11:50:33 AM need IBT on grounding electrode per 250.94

 04/28/2020TEMPORARY POWERRANDY TRIVETTEAPPROVED

 05/05/2020BLDG FINAL CERT OF COMPRANDY TRIVETTEREJECTED5/5/2020 3:07:18 PM need footing approval letter uploaded, and Mooresville approvals-only

 05/05/2020FIREPLACE FINALRANDY TRIVETTEAPPROVED

 05/05/2020GARAGE PORCH SLABRANDY TRIVETTEAPPROVED

 05/05/2020GRADING RESRANDY TRIVETTEAPPROVED

 05/05/2020LOCATION SETBACKSRANDY TRIVETTEAPPROVED

BLDG FINAL CERT OF COMPRANDY TRIVETTE

BACKFLOWMARY A BOLIEKAPPROVED

UTILITY FINALGary L HarkeyAPPROVED

ZONING FINALGary L HarkeyAPPROVED

 05/08/2020BLDG FINAL CERT OF COMPRANDY TRIVETTEAPPROVED5/5/2020 3:07:22 PM need footing approval letter uploaded, and Mooresville approvals-only

 05/08/2020CERT OF OCCUPANCYRANDY TRIVETTEAPPROVED

 05/08/2020CERT OF OCCUPANCYRANDY TRIVETTEAPPROVED

 05/08/2020FOOTINGRANDY TRIVETTEAPPROVED11/5/2019 2:20:22 PM partial-ok pending soil report 5/8/2020 11:37:57 AM letter in file

 05/08/2020FRAMINGRANDY TRIVETTEAPPROVED2/19/2020 2:33:08 PM * need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE * 2/21/2020 1:25:53 PM engineer letter in file on leaving hanger on lvl in garage right side up 2/21/2020 1:25:53 PM * missing nuts,washers & anchor bolts @ various places * concealed flange hanger @ cantilevered LVL in garage install incorrectly (needs to be inverted per plan) * confirm that truss hangers on 10-C trusses(bonus rm) are correct * missing simpson hold down brackets per plan * seal holes/gaps @ PL pipes @ sole plate( various places) * tighten crack/gap @ 2 ply girder truss @ upstairs front gable wall * 2/21/2020 1:25:53 PM * need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE *

 05/08/2020SHEATHING AND FLASHINGRANDY TRIVETTEAPPROVED

CERT OF OCCUPANCYRANDY TRIVETTE