| ELEC UNDERGROUND | | | | |
|
| ELECTRICAL SLAB | | | | |
|
11/05/2019 | FOOTING | RANDY TRIVETTE | PARTIAL | | 11/5/2019 2:20:17 PM
partial-ok pending soil report
|
|
11/27/2019 | FOUNDATION | RANDY TRIVETTE | PARTIAL | | 11/27/2019 12:14:24 PM
BLOCK OK ,,NEED SLAB INSULATION ON INSIDE OF FOUNDATION WALL,,WILL CHECK AT SLAB
|
|
12/04/2019 | PLUMBING SLAB | RANDY TRIVETTE | APPROVED | | |
|
12/04/2019 | SEWER | RANDY TRIVETTE | REJECTED | | 12/4/2019 2:14:26 PM
not ready
|
|
12/04/2019 | WATER SUPPLY | RANDY TRIVETTE | REJECTED | | 12/4/2019 2:14:30 PM
not ready
|
|
12/06/2019 | SEWER | RANDY TRIVETTE | APPROVED | | 12/4/2019 2:14:30 PM
not ready
|
|
12/06/2019 | WATER SUPPLY | RANDY TRIVETTE | APPROVED | | 12/4/2019 2:14:34 PM
not ready
|
|
12/06/2019 | FOUNDATION | RANDY TRIVETTE | APPROVED | | 11/27/2019 12:14:28 PM
BLOCK OK ,,NEED SLAB INSULATION ON INSIDE OF FOUNDATION WALL,,WILL CHECK AT SLAB
|
|
12/06/2019 | SLAB | RANDY TRIVETTE | APPROVED | | |
|
12/20/2019 | SAW SERVICE | RANDY TRIVETTE | APPROVED | | |
|
12/20/2019 | SAW SERVICE | RANDY TRIVETTE | APPROVED | | |
|
| COMPLETE PERMIT** | | | | |
|
01/21/2020 | SHEATHING AND FLASHING | RANDY TRIVETTE | APPROVED | | |
|
01/28/2020 | SAW SERVICE | RANDY TRIVETTE | APPROVED | | |
|
01/28/2020 | PLUMBING ROUGH | RANDY TRIVETTE | APPROVED | eTRAKiT Inspection Request | 1/27/2020 11:51:52 AM
1/27/2020 11:51 AM PRICE BROTHERS, INC
Contact Name: PRICE BROTHERS, INC
Site Address: 240 MADELIA PL
Phone: 7045886110
e-Mail: PBIPURCHASING@PRICEBROTHERSINC.COM
|
|
01/31/2020 | LOW VOLTAGE ROUGH | RANDY TRIVETTE | APPROVED | | 1/30/2020 10:13:03 AM
1/30/2020 10:13 AM CPI SECURITY SYSTEMS INC
Contact Name: CPI SECURITY SYSTEMS INC
Site Address: 240 MADELIA PL
Phone: 7049456133
e-Mail: newconstruction@cpisecurity.com
|
|
02/04/2020 | GAS PIPING ROUGH | GARY WRIGHT | APPROVED | | |
|
02/04/2020 | MECHANICAL ROUGH | GARY WRIGHT | APPROVED | | |
|
02/07/2020 | ELECTRICAL ROUGH | GARY WRIGHT | APPROVED | | |
|
02/13/2020 | FRAMING | MARK POPE | REJECTED | | 2/13/2020 4:28:25 PM
* missing nuts,washers & anchor bolts @ various places * concealed flange hanger @ cantilevered LVL in garage install incorrectly (needs to be inverted per plan) * confirm that truss hangers on 10-C trusses(bonus rm) are correct * missing simpson hold down brackets per plan * seal holes/gaps @ PL pipes @ sole plate( various places) * tighten crack/gap @ 2 ply girder truss @ upstairs front gable wall *
|
|
02/19/2020 | FIREPLACE ROUGH | MARK POPE | APPROVED | | |
|
02/19/2020 | FRAMING | MARK POPE | PARTIAL | | 2/19/2020 2:33:04 PM
* need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE *
|
|
02/21/2020 | FRAMING | RANDY TRIVETTE | APPROVED | | 2/13/2020 4:28:58 PM
* missing nuts,washers & anchor bolts @ various places * concealed flange hanger @ cantilevered LVL in garage install incorrectly (needs to be inverted per plan) * confirm that truss hangers on 10-C trusses(bonus rm) are correct * missing simpson hold down brackets per plan * seal holes/gaps @ PL pipes @ sole plate( various places) * tighten crack/gap @ 2 ply girder truss @ upstairs front gable wall *
2/19/2020 2:33:08 PM
* need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE *
2/21/2020 1:25:50 PM
engineer letter in file on leaving hanger on lvl in garage right side up
|
|
02/21/2020 | FRAMING | RANDY TRIVETTE | APPROVED | | 2/21/2020 2:44:50 PM
eng letter in file for inverted hanger
|
|
02/26/2020 | INSULATION | RANDY TRIVETTE | APPROVED | | |
|
| INSULATION | RANDY TRIVETTE | | | |
|
03/17/2020 | SHOWER PAN | RANDY TRIVETTE | APPROVED | eTRAKiT Inspection Request | 3/16/2020 10:12:19 AM
3/16/2020 10:12 AM PRICE BROTHERS, INC
Contact Name: PRICE BROTHERS, INC
Site Address: 240 MADELIA PL
Phone: 7045886110
e-Mail: dray@PRICEBROTHERSINC.COM
|
|
04/06/2020 | GAS PIPING FINAL | RANDY TRIVETTE | APPROVED | | |
|
04/07/2020 | MECHANICAL FINAL CERT OF COMP | RANDY TRIVETTE | APPROVED | | |
|
04/09/2020 | LOW VOLTAGE FINAL | RONNIE BROOME | APPROVED | | 4/8/2020 1:59:46 PM
4/8/2020 1:59 PM CPI SECURITY SYSTEMS INC
Contact Name: CPI SECURITY SYSTEMS INC
Site Address: 240 MADELIA PL
Phone: 7049456133
e-Mail: newconstruction@cpisecurity.com
|
|
04/14/2020 | ELECTRICAL FINAL CERT OF COMP | RANDY TRIVETTE | REJECTED | | 4/14/2020 2:51:31 PM
need ground rods,,coach light on garage,,25amp max breaker on #1 A/C
|
|
04/14/2020 | PLUMBING FINAL CERT OF COMP | RANDY TRIVETTE | APPROVED | eTRAKiT Inspection Request | 4/13/2020 3:56:22 PM
4/13/2020 3:56 PM PRICE BROTHERS, INC
Contact Name: PRICE BROTHERS, INC
Site Address: 240 MADELIA PL
Phone: 7045886110
e-Mail: pbipurchasing@PRICEBROTHERSINC.COM
|
|
04/16/2020 | ELECTRICAL FINAL CERT OF COMP | RANDY TRIVETTE | REJECTED | | 4/14/2020 2:51:36 PM
need ground rods,,coach light on garage,,25amp max breaker on #1 A/C
4/16/2020 11:50:26 AM
need IBT on grounding electrode per 250.94
|
|
04/20/2020 | ELECTRICAL FINAL CERT OF COMP | RANDY TRIVETTE | APPROVED | | 4/16/2020 11:50:33 AM
need ground rods,,coach light on garage,,25amp max breaker on #1 A/C
4/16/2020 11:50:33 AM
need IBT on grounding electrode per 250.94
|
|
04/28/2020 | TEMPORARY POWER | RANDY TRIVETTE | APPROVED | | |
|
05/05/2020 | BLDG FINAL CERT OF COMP | RANDY TRIVETTE | REJECTED | | 5/5/2020 3:07:18 PM
need footing approval letter uploaded, and Mooresville approvals-only
|
|
05/05/2020 | FIREPLACE FINAL | RANDY TRIVETTE | APPROVED | | |
|
05/05/2020 | GARAGE PORCH SLAB | RANDY TRIVETTE | APPROVED | | |
|
05/05/2020 | GRADING RES | RANDY TRIVETTE | APPROVED | | |
|
05/05/2020 | LOCATION SETBACKS | RANDY TRIVETTE | APPROVED | | |
|
| BLDG FINAL CERT OF COMP | RANDY TRIVETTE | | | |
|
| BACKFLOW | MARY A BOLIEK | APPROVED | | |
|
| UTILITY FINAL | Gary L Harkey | APPROVED | | |
|
| ZONING FINAL | Gary L Harkey | APPROVED | | |
|
05/08/2020 | BLDG FINAL CERT OF COMP | RANDY TRIVETTE | APPROVED | | 5/5/2020 3:07:22 PM
need footing approval letter uploaded, and Mooresville approvals-only
|
|
05/08/2020 | CERT OF OCCUPANCY | RANDY TRIVETTE | APPROVED | | |
|
05/08/2020 | CERT OF OCCUPANCY | RANDY TRIVETTE | APPROVED | | |
|
05/08/2020 | FOOTING | RANDY TRIVETTE | APPROVED | | 11/5/2019 2:20:22 PM
partial-ok pending soil report
5/8/2020 11:37:57 AM
letter in file
|
|
05/08/2020 | FRAMING | RANDY TRIVETTE | APPROVED | | 2/19/2020 2:33:08 PM
* need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE *
2/21/2020 1:25:53 PM
engineer letter in file on leaving hanger on lvl in garage right side up
2/21/2020 1:25:53 PM
* missing nuts,washers & anchor bolts @ various places * concealed flange hanger @ cantilevered LVL in garage install incorrectly (needs to be inverted per plan) * confirm that truss hangers on 10-C trusses(bonus rm) are correct * missing simpson hold down brackets per plan * seal holes/gaps @ PL pipes @ sole plate( various places) * tighten crack/gap @ 2 ply girder truss @ upstairs front gable wall *
2/21/2020 1:25:53 PM
* need engineering on concealed hanger issue & truss hanger varification on 3 bonus rm trusses * install air barrier on backside of bonus rm knee walls * foam penetrations in dead chases & @ cracks & penetrations @ blocking under knee walls of bonus rm * clean out dead chase @ FP vent pipe up & down * busted i-joist flange @ mid living rm on LVL girder side( check w/ mfg on possible repair if needed * OK TO INSULATE *
|
|
05/08/2020 | SHEATHING AND FLASHING | RANDY TRIVETTE | APPROVED | | |
|
| CERT OF OCCUPANCY | RANDY TRIVETTE | | | |
|