Permit No. AP-301176 Permit Type   BUILDING RESIDENTIAL Site Address   280 BIG INDIAN LOOP
MOORESVILLE, NC 28117
Applied   09/24/2019 Applicant   DIANE PASSKIEWIZZ
Approved   12/11/2019 Owner   HANCOCK ALTON+CHERLY M
Issued   12/11/2019 Contractor   Schumacher Homes
Parent Permit No.   Description   SFD
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

ELECTRICAL SLAB

PLUMBING SLAB

CHANGE OF USE

TEMPORARY OCCUPANCY

GARAGE PORCH SLAB

MARRIAGE WALL

OPEN FLOOR FRAMING

BUILDING ABOVE CEILING

COMPLETE PERMIT**

 01/07/2020FOOTINGJEFF CHUBYAPPROVEDHAS LETTER1/7/2020 10:09:24 AM put in box 1/7/2020 10:11:14 AM can do saw service, location setback and grading with this. They are scheduled for tomorrow. 1/7/2020 12:57:18 PM Engineer report and engineer compliance report for inspection on file. Soil report on file.

 01/07/2020FOUNDATIONJEFF CHUBYAPPROVEDWATER PROOFING ALSO

 01/07/2020FOUNDATIONJEFF CHUBYAPPROVEDTERMITE CONTROL

 01/07/2020GRADING RESJEFF CHUBYPARTIAL1/7/2020 12:57:26 PM Pending Final grade

 01/07/2020LOCATION SETBACKSJEFF CHUBYAPPROVED1/7/2020 12:57:30 PM Property lines flagged

 01/07/2020SAW SERVICEJACK HARWELLAPPROVED

 01/14/2020FRAMINGMARK POPEPARTIAL1/14/2020 10:34:20 AM * open floor /OK *

 01/30/2020SLABBRADLEY NICHOLSONAPPROVEDPORCH & GARAGE SLAB1/30/2020 12:59:48 PM Garage, front & rear porches ok

 02/03/2020PLUMBING ROUGHMARK POPEAPPROVED

 02/14/2020ELECTRICAL ROUGHBRADLEY NICHOLSONAPPROVED

 02/14/2020MECHANICAL ROUGHBRADLEY NICHOLSONREJECTED2/14/2020 9:54:55 AM not ready

 02/14/2020FRAMINGBRADLEY NICHOLSONREJECTED1/14/2020 10:34:28 AM * open floor /OK * 2/14/2020 9:55:01 AM need all trade rough approvals, add staps on each side of header at master bedroom window,double stapping at garage portal frame

 02/14/2020LOW VOLTAGE ROUGHBRADLEY NICHOLSONAPPROVED

 02/17/2020SHEATHING AND FLASHINGBRADLEY NICHOLSONAPPROVED

 02/17/2020MECHANICAL ROUGHBRADLEY NICHOLSONAPPROVED2/14/2020 9:55:00 AM not ready

 02/17/2020FRAMINGBRADLEY NICHOLSONAPPROVED2/14/2020 9:55:07 AM need all trade rough approvals, add staps on each side of header at master bedroom window,double stapping at garage portal frame 2/14/2020 9:55:08 AM * open floor /OK *

 02/17/2020GAS PIPING ROUGHBRADLEY NICHOLSONAPPROVED

 02/20/2020INSULATIONBRADLEY NICHOLSONPARTIAL2/20/2020 2:44:34 PM Pending seal around frame on front door, complete wall insulation by same door

 02/21/2020INSULATIONBRADLEY NICHOLSONAPPROVED2/20/2020 2:44:39 PM Pending seal around frame on front door, complete wall insulation by same door

 03/16/2020OPERATIONMARIA DOTSONAPPROVED

OPERATIONMARIA DOTSONAPPROVED

 03/16/2020SHOWER PANMARK POPEAPPROVED3/16/2020 4:07:14 PM * master shower *

 03/30/2020ELEC UNDERGROUNDDANA LAPISHAPPROVED3/30/2020 2:46:59 PM well

 03/30/2020TEMPORARY POWERDANA LAPISHAPPROVED

 04/08/2020PLUMBING FINAL CERT OF COMPMARK POPEREJECTED4/8/2020 12:02:56 PM * install pipe @ pop off valve @ W/H * insulate water lines @ W/H * complete set out of half bath * seal annular space @ sewer sleeve inside of crawlspace, also seal foundation wall @ sewer sleeve inside of crawlspace * water supply never inspected. need to see depth @ several locations *

 04/08/2020SEWERMARK POPEAPPROVED

 04/08/2020WATER SUPPLYMARK POPEREJECTED4/8/2020 12:03:03 PM * water supply never inspected. need to see depth @ several location *

 04/14/2020MECHANICAL FINAL CERT OF COMPDANA LAPISHAPPROVED2/17/2020 9:49:49 AM check return ducts at final, not installed on rough

 04/14/2020PLUMBING FINAL CERT OF COMPDANA LAPISHAPPROVED4/8/2020 12:03:00 PM * install pipe @ pop off valve @ W/H * insulate water lines @ W/H * complete set out of half bath * seal annular space @ sewer sleeve inside of crawlspace, also seal foundation wall @ sewer sleeve inside of crawlspace * water supply never inspected. need to see depth @ several locations *

 04/14/2020WATER SUPPLYDANA LAPISHAPPROVED4/8/2020 12:03:31 PM * water supply never inspected. need to see depth @ several location * 4/14/2020 11:10:40 AM Inspected at same time Electrical well underground

 04/14/2020GAS PIPING FINALDANA LAPISHREJECTED4/14/2020 11:10:34 AM Need to disconnect gas & test gas piping again at final / Regulator installed in attic is gas pressure 2LB. or 1/2lb. Install proper regulators if 2LB.system

 04/14/2020ELECTRICAL FINAL CERT OF COMPDANA LAPISHREJECTED4/14/2020 11:28:45 AM Bond gas piping when using Trac piping

 04/14/2020BLDG FINAL CERT OF COMPDANA LAPISHREJECTED4/14/2020 1:23:54 PM Need Energy Certificate & Duct leakage test/ All health dept. inspections need to be approved & entered into system / Install house numbers

 04/17/2020BLDG FINAL CERT OF COMPDANA LAPISHREJECTED4/14/2020 1:23:57 PM Need Energy Certificate & Duct leakage test/ All health dept. inspections need to be approved & entered into system / Install house numbers 4/17/2020 1:30:07 PM Same as last visit

 04/17/2020ELECTRICAL FINAL CERT OF COMPDANA LAPISHREJECTED4/17/2020 5:08:54 PM Need to bond CSST gas piping

 04/17/2020GAS PIPING FINALDANA LAPISHREJECTED4/17/2020 5:15:26 PM Need Test at final / verify gas supply 1/2lb. or 2lb. & label & install regulators if needed

 04/21/2020GW-1MARIA DOTSONAPPROVED

 11/19/2019WELL ABANDONMENTPATRICK BOYLEAPPROVED11/13/2019 1:27:57 PM Could not enter Date in box but abandonment was done on 11/13/19

 03/11/2020WELL GROUTINGJAMES BOGGSAPPROVEDPassed 3-11-2020

 04/22/2020WELL HEADBEN BOTKINSAPPROVEDAPPROVED BY BB

 04/22/2020ELECTRICAL FINAL CERT OF COMPDANA LAPISHAPPROVED

 04/22/2020GAS PIPING FINALDANA LAPISHAPPROVED

GRADING RESDANA LAPISHAPPROVED1/7/2020 12:57:29 PM Pending Final grade

LOW VOLTAGE FINALDANA LAPISHAPPROVED

 04/22/2020BLDG FINAL CERT OF COMPDANA LAPISHAPPROVED4/17/2020 1:30:11 PM Need Energy Certificate & Duct leakage test/ All health dept. inspections need to be approved & entered into system / Install house numbers 4/17/2020 1:30:11 PM Same as last visit

CERT OF OCCUPANCYDANA LAPISHAPPROVED

ENERGY ENVELOPEDANA LAPISHAPPROVED

COMPLETE PERMIT**DANA LAPISHAPPROVED